BSDL Files Library for JTAG

The only free public library that contains thousands of BSDL (Boundary Scan Description Language) models to use with BScan/JTAG tools

BSDL model: XC1802

--$ XILINX$RCSfile: xc1802.bsd,v $ 
--$ XILINX$Revision: 1.3 $ 
-- 
-- BSDL file for device XC1802, package DIE_BOND 
-- Xilinx, Inc. $State: ADVANCED $ $Date: May 23, 2000 11:05:24 $
--
-- For technical support, contact Xilinx as follows:
--      North America   1-800-255-7778          hotline@xilinx.com
--      United Kingdom  (44) 1932 820821        ukhelp@xilinx.com
--      France          (33) 1 3463 0100        frhelp@xilinx.com
--      Germany         (49) 89 991 54930       dlhelp@xilinx.com
--      Japan           (81) 3-3297-9163        jhotline@xilinx.com

entity XC1802 is

generic (PHYSICAL_PIN_MAP : string := "DIE_BOND" );

port ( 
	TDI: in bit;
	TMS: in bit;
	Gnd_2: linkage bit;
	TCK: in bit;
	Vcco_1: linkage bit;
	D4: out bit;
	CF: out bit;
	Reset_OE: inout bit;
	D6: out bit;
	CE: in bit;
	Vcco_2: linkage bit;
	Vcc_1: linkage bit;
	Gnd_3: linkage bit;
	D7: out bit;
	CEO: out bit;
	D5: out bit;
	Vcco_3: linkage bit;
	D3: out bit;
	Gnd_4: linkage bit;
	D1: out bit;
	TDO: out bit;
	Vpp: linkage bit;
	Vcco_4: linkage bit;
	Vcc_2: linkage bit;
	D0: out bit;
	Gnd_1: linkage bit;
	D2: out bit;
	CLK: in bit
); --end port list

use STD_1149_1_1994.all;

attribute COMPONENT_CONFORMANCE of XC1802 : entity is
        "STD_1149_1_1993";

attribute PIN_MAP of XC1802 : entity is PHYSICAL_PIN_MAP;

constant DIE_BOND: PIN_MAP_STRING:=
	"TDI:PAD3," & 
	"TMS:PAD5," & 
	"Gnd_2:PAD6," & 
	"TCK:PAD7," & 
	"Vcco_1:PAD8," & 
	"D4:PAD9," & 
	"CF:PAD10," & 
	"Reset_OE:PAD13," & 
	"D6:PAD14," & 
	"CE:PAD15," & 
	"Vcco_2:PAD16," & 
	"Vcc_1:PAD17," & 
	"Gnd_3:PAD18," & 
	"D7:PAD19," & 
	"CEO:PAD21," & 
	"D5:PAD25," & 
	"Vcco_3:PAD26," & 
	"D3:PAD27," & 
	"Gnd_4:PAD28," & 
	"D1:PAD29," & 
	"TDO:PAD31," & 
	"Vpp:PAD35," & 
	"Vcco_4:PAD36," & 
	"Vcc_2:PAD38," & 
	"D0:PAD40," & 
	"Gnd_1:PAD41," & 
	"D2:PAD42," & 
	"CLK:PAD43";

attribute TAP_SCAN_IN    of TDI : signal is true;
attribute TAP_SCAN_MODE  of TMS : signal is true;
attribute TAP_SCAN_OUT   of TDO : signal is true;

attribute TAP_SCAN_CLOCK of TCK : signal is (1.00e+07, BOTH);

attribute INSTRUCTION_LENGTH of XC1802 : entity is 8;

attribute INSTRUCTION_OPCODE of XC1802 : entity is
	"BYPASS ( 11111111)," &
	"SAMPLE ( 00000001)," &
	"EXTEST ( 00000000)," &
	"IDCODE ( 11111110)," &
	"USERCODE ( 11111101)," &
	"HIGHZ ( 11111100)," &
	"CLAMP ( 11111010)," &
	"ISPEN ( 11101000)," &
	"ISPENC ( 11101001)," &
	"FPGM ( 11101010)," &
	"FADDR ( 11101011)," &
	"FVFY0 ( 11101111)," &
	"FVFY1 ( 11111000)," &
	"FVFY3 ( 11100010)," &
	"FVFY6 ( 11100110)," &
	"FERASE ( 11101100)," &
	"SERASE ( 00001010)," &
	"FDATA0 ( 11101101)," &
	"FDATA3 ( 11110011)," &
	"FBLANK0 ( 11100101)," &
	"FBLANK3 ( 11100001)," &
	"FBLANK6 ( 11100100)," &
	"NORMRST ( 11110000)," &
	"CONFIG ( 11101110)," &
	"priv1 ( 11110001)," &
	"priv2 ( 11100011)," &
	"priv3 ( 11100111)," &
	"priv4 ( 11110110)," &
	"priv5 ( 11100000)," &
	"priv6 ( 11110111)," &
	"priv7 ( 11110010)," &
	"priv8 ( 11110100)," &
	"priv9 ( 11110101)"; 

attribute INSTRUCTION_CAPTURE of XC1802: entity is "000XXX01";

attribute INSTRUCTION_PRIVATE of XC1802: entity is
	"priv1," &
	"priv2," &
	"priv3," &
	"priv4," &
	"priv5," &
	"priv6," &
	"priv7," &
	"priv8," &
	"priv9"; 

attribute IDCODE_REGISTER of XC1802: entity is
        "0000" &                -- version
        "0101000000000101" &    -- part number
        "00001001001" &         -- manufacturer's id
        "1";                    -- required by standard

attribute USERCODE_REGISTER of XC1802: entity is
        "XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX";


attribute REGISTER_ACCESS of XC1802 : entity is
        "BYPASS ( BYPASS, HIGHZ, CLAMP, FPGM, NORMRST, CONFIG )," &
        "ISPENABLE[6] ( ISPEN, ISPENC )," &
        "DATA0[4096] ( FVFY0, FDATA0 ),"&
        "DATA1[2097152] ( FVFY1, FBLANK0 ),"&
        "DATA3[3] ( FVFY3, FDATA3, FBLANK3 ),"&
        "ADDRESS[16] ( FADDR, FERASE, SERASE ),"&
        "DEVICE_ID ( IDCODE, USERCODE ),"&
        "USERCODEV[32] ( FVFY6, FBLANK6 )";
         -- Readback image of the USERCODE register contents
attribute BOUNDARY_LENGTH of XC1802 : entity is 25; 

attribute BOUNDARY_REGISTER of XC1802 : entity is
	"   0 (BC_1, CLK, input, X)," &
	"   1 (BC_1, *, controlr, 0)," &
	"   2 (BC_1, D2, output3, X, 1, 0, Z)," &
	"   3 (BC_1, *, controlr, 0)," &
	"   4 (BC_1, D0, output3, X, 3, 0, Z)," &
	"   5 (BC_1, *, controlr, 0)," &
	"   6 (BC_1, D1, output3, X, 5, 0, Z)," &
	"   7 (BC_1, *, controlr, 0)," &
	"   8 (BC_1, D3, output3, X, 7, 0, Z)," &
	"   9 (BC_1, *, controlr, 0)," &
	"   10 (BC_1, D5, output3, X, 9, 0, Z)," &
	"   11 (BC_1, *, controlr, 0)," &
	"   12 (BC_1, CEO, output3, X, 11, 0, Z)," &
	"   13 (BC_1, *, controlr, 0)," &
	"   14 (BC_1, D7, output3, X, 13, 0, Z)," &
	"   15 (BC_1, CE, input, X)," &
	"   16 (BC_1, *, controlr, 0)," &
	"   17 (BC_1, D6, output3, X, 16, 0, Z)," &
	"   18 (BC_1, *, controlr, 0)," &
	"   19 (BC_1, Reset_OE, output3, X, 18, 0, Z)," &
	"   20 (BC_1, Reset_OE, input, X)," &
	"   21 (BC_1, *, controlr, 0)," &
	"   22 (BC_1, CF, output3, X, 21, 0, Z)," &
	"   23 (BC_1, *, controlr, 0)," &
	"   24 (BC_1, D4, output3, X, 23, 0, Z)";